Version 2.585
Updated 2 years ago
Changelog Calibration and balancing process improved [calibration corresponds to "full charge" after 100% & "discharge" after 0%, balancing is optimized to ensure "full charge" of the power battery].
Improvement of SOC determination
Access Point (Wi-Fi) can be disabled
New display: "Balancing" process in RCT Power App as "SOC_Target = 100%".
New country standards: Sweden SS-EN50549-1 and China CN-NB_T32004_2018_B
Version 2.545
Updated 2 years ago
Changelog New country codes :
Denmark , Belgium , Czech Republic : EN 50549 1, France: VFR2019
Optimization of global MPP algorithm
Bugfix: false settings of battery lifecyle influencing parameters blocked
Impoved connectivity via WIFI & Ethernet
Data export via Android 11 ( excluding Gmail App)
Changes of automatic updates for Master/Slave systems
User friendly display settings brightness , contrast
Version 2.515
Updated 2 years ago
Changelog Fixed deadlock when entering wrong router wifi password
Control 5369:
Fixed cyclic display flashing without active access
Optimization behaviour of trickle charge in connection with Power Switch
Improved control behaviourfor more stable feed-in function
Frequent switching of grid relays at low PV-power improved
Increased robustness for digital inputs in conjunction with PowerStorage DC8_1
Optimized stability of WiFi connection
Version 2.500
Updated 3 years ago
Changelog Improvement of update behaviour on older end devices
Update parameter set Austria „Tor Erzeuger“
Control 5291:
Bugfix at Backup power operation with min. SOC
Optimization of Backup power function for PSDC8.0 and PSDC10.0
Revision of current measurement for more stable feed-in behaviour
Version 2.488
Updated 3 years ago
Changelog Control 5234
Updated parameter file.
Improvement of starting behaviour.
Version 2.486
Updated 3 years ago
Changelog Prevention of manual sensor configuration
Reference to sensor arrangement at negative house load
Possibility of time-controlled charge management
Intelligent calibration function integrated
Minor adjustments in App interface
Fixing of bugs in prediction function
Control 5198:
Bug fixed in power calculation at night
Optimization of battery backup operation
BMS 5185:
Improved self-diagnosis
Fixing of minor bugs
Version 2.461
Updated 4 years ago
Changelog Control 4952
Stability improvement regarding high battery power during night time
Fixed WiFi issues with router IP redistribution
Version 2.456
Updated 4 years ago
Version 2.309
Updated 6 years ago
Changelog Control 4366
Battery current control and calibration bugs fixed.
Synchronization bug fix by return from island.
Networking for PV-plant.
New COM communication protocol.
Switching to island time reduced to ca. 4s.
Prevent charging DC-Link in battery passive mode.
S0-signal for grid-feed power corrected.
Bug fix in MPP-tracker.
Start by high DC voltages bug fixed.
BMS update integrated.
Few more enhancements.
Version 2.302
Updated 6 years ago
Changelog Control 4333
Corrected battery calibration procedure.