Discover

Topics

Process to Signal (4 to 20) mA

Process to Signal (4 to 20) mA APK

Process to Signal (4 to 20) mA APK

1.5.0 FreeStatus Instruments ⇣ Download APK (1.77 MB)

Converts an Engineering variable (PSI, °C/ etc.) to an output (mA, mV/ etc.).

What's Process to Signal (4 to 20) mA APK?

Process to Signal (4 to 20) mA is a app for Android, It's developed by Status Instruments author.
First released on google play in 9 years ago and latest version released in 8 years ago.
This app has 45.9K download times on Google play and rated as 4.48 stars with 177 rated times.
This product is an app in Tools category. More infomartion of Process to Signal (4 to 20) mA on google play
Status Instruments’ free App for converting a process signal value, in any engineering unit, into a control signal in milli amps, milli volts, or volts.
For use in temperature measurement, process control, and signal conditioning


The input engineering range and output signal range are entered into the calculator.


Typical use would be for a control or alarm system monitoring the temperature in a vessel. A temperature transmitter would be used to generate a mA signal to represent °C.

Example
Input range in engineering units (0 to 100)°C ; output signal range (4 to 20) mA [sometimes given as 4-20mA]

A point input value can entered in °C and the corresponding output signal value in mA calculated.

An output signal value in mA can entered and the corresponding input temperature in °C calculated

Typical engineering units
inH2, inHg, ftH2O, mmH2O, mmHg, psi, bars, mbar, g/sqcm, kg/sqcm, Pa, KPa, Torr, Atmosph, Cuft/min , gal/min, L/min, Impgal/min, Cum/h, ft/s, m/s, gals/s, MMgal/d, L/s, ML/d, Cuft/s, Cuft/d, Cum/s, Cum/d, Impgal/h, Impgal/d, Deg C, Deg F, Deg R, Kelvin, Mv, ohms, Hz, mA, gal, L, Impgal, Cum, Ft, M, Bbl, In, Cm, Mm, Min, S, H, D, cSt, cP, uMho, %, V, pH, g, kg, Met Ton, Lb, STon, LTon, mS/cm, uS/cm,N, Nm, g/s, g/min, g/h, kg/s, kg/min,kg/h,kg/d, Met Ton/min, Met Ton/h, Met Ton/d, lb/s, lb/min, lb/h, lb/d, STon/min, STon/h, STon/d, LTon/h, LTon/d, Datherm, SGU, g/Cucm, kg/Cum, lb/gal, lb/Cuft, g/mL, kg/L, g/L, lb/Cuin, STon/Cutd, degTwad, degBrix, degBaum hv, degBaum lt, degAPI, % sol-wt, % sol-vol, degBall, proof/vol, proof/mass, bush, Cuyd, Cuft, Cuin, in/s, in/min, ft/min, deg/s, rev/s, rpm, m/h, NmlCum/h, NmlL/h, StdCuft/min, bbl(liq), Cuft/hr, Cum/min, bbl/s, bbl/m, bbl/h, bbl/d, gal/h, impgal/s, L/h, Ppm, Mcal/h, Mj/h, Btu/h, Deg, Rad, inH2O @ 60°C, ug/L, ug/Cum,%Cs, Vol%, % Stm Quad, ft.in 16, Cuft/Lb, pF, mL/L, uL/L, % plato, % LEL, Mcal, KO, MJ, Btu, NmlCum, Nm/L, StdCuft, Ppb, gal/d, hL, MPa, inH2O @ 4°C, mmH2O @ 4°C, & uV.


Note: the values represent ideals, no tolerances have been applied and no allowances for input source errors, or output measurement equipment errors have been used.