Discover

Topics

EWP 2011 Electrical Wiring Pro

EWP 2011 Electrical Wiring Pro APK

EWP 2011 Electrical Wiring Pro APK

Varies with device FreeIntineo LLC

What's EWP 2011 Electrical Wiring Pro APK?

EWP 2011 Electrical Wiring Pro is a app for Android, It's developed by Intineo LLC author.
First released on google play in 8 years ago and latest version released in 8 years ago.
This app has 0 download times on Google play and rated as 4.55 stars with 700 rated times.
This product is an app in Productivity category. More infomartion of EWP 2011 Electrical Wiring Pro on google play
Electrical Wiring Pro is now EWP 2011. A new separate app, EWP 2014, has the same
functionality, but is updated for the 2014 NEC. EWP 2014 will receive new features
and EWP 2011 is now in maintenance/bugfix mode.

** If you are thinking of buying this app, you probably want to buy EWP 2014 instead.**

Over 40 Useful Electrical Calculators & Tools, each of which could be an app
in its own right.

For Electricians, Power Engineers and other Electrical Professionals.
Written by a working Electrician using it on a daily basis.

Calculations per National Electrical Code 2005, 2008 and
2011.

o NEW Residential/Load Calculations
- Single Family Dwelling
- Multi Family Dwelling
- Range Calculations
- Send results via email for verification and documentation

o Ampacity / Wire Size (AWG only)
- Wire Size -> Ampacity
- Ampacity Needed -> Wire Size
- Voltage Drop -> Wire Size
- Dwelling Service Size
- GEC Size
- EGC Size
- New Ampacity section includes
o Improved user interface,
o NEC 2005, 2008 and 2011 (the updates are accounted for by the app)
o > 700 locations with Ambient Temps

o Boxes / Cover
- Box Size from Wires / Devices
- Box Size from Cables / Devices
- Standard Box and Typical Plaster Ring INfo
- Pull Box Sizing

o Conduit Fill
- Wires -> Conduit Size Needed
- Wires/Conduit -> % full
- Maximum Wires/Conduit
- Conduit Size Details
- Wire Size Details

o Conduit Bending
- Standard and Rolled Offsets
- Parallel Offsets
- 3-point Saddle
- Round and rectangular corner obstacles
- Segment Bends
- Minimum Bend Radius One-Shot/Full Shoe or Other bends

o Voltage Drop
- Required voltage or % drop -> Wire Size
- Voltage Drop Calculation
- Maximum Length for voltage or % drop
- Maximum Load for voltage or % drop
- Impedance given wire length

o Motors
- FLC, Wire, Breaker, Heater, Starter, Conduit etc. Sizing
- Locked Rotor Current
- KVAR Capacitor Correction
- NEMA Motor Dimensions

oTransformers
- Basic Transformer Sizing
- Overcurrent Protection Device Sizing
- Transformer Faults
- Delta-Wye configuration

o Wire / Device info
- Standard Receptacle configurations
- AWG-Metric wire size comparison
- Ethernet TIA-568A/B Color Codes
- RJ 11/14/25 Color Codes
- Resistor Color Codes

o Other
- In-Foot <-> Metric, Construction Fraction <-> Decimal converter
- Parallel Load Calculator
- Pire Wheel / Ohms Law
- Cover Depth
- Temperature Conversion for 8 different scales

If you would like to report bugs or suggestions, please send them to:
support aatt intineo dot com
rather than use the comment mechanism so we can respond
directly -- thank you.